Mazak PT20, M730L: R.D. Alarms reset 1393, 1394, 1395, 1396, 1397
1393 RD Relocation Detected
1394 RD Communication Error
1395 RD Battery Change Time Exceeded
1396 RD Low Battery
1397 RD Battery Not Mounted
Steps applied on the EXCEL to decode the password:
STEP1: Convert machine serial number to HEX
STEP2: Get day of current date
STEP3: Get month of current date times #31
STEP4: Get year of current date times #372
STEP5: Select last two digits of HEX from STEP1
STEP6: SUM DEC from STEP2, 3 & 4
STEP7: Convert STEP6 number to HEX:
STEP8: Select first two digits of HEX from STEP7
STEP9: Select HEX from STEP5
STEP10: Fix variable #22
STEP11: Select last two digits of HEX from STEP7
STEP12: Fix variable #2
STEP13: Create HEX password with STEP8,9,10 & 11-12
STEP14: Concatenate HEX password
STEP15: Convert HEX password to DEC (Parameter #18238)